KLD-BMS Series Harmonic Protector

Harmonic control product developed for precise instruments on the user side that are susceptible to various kinds of interferences and result in various faults. It can absorb high-frequency pulse spike and high-frequency noise signals to protect sensitive equipment on the user side.

PRODUCT OVERVIEW

As science and technology continues to develop, harmonics generated by nonlinear modern power equipment and devices, such as computers, lighting control systems, communication systems, network control equipment, a variety of digital office equipment, light regulation and control systems, UPS, CNC machine tools, rectifiers, precise instruments, electronic control mechanisms, etc., result in a harsh harmonic environment, posing s great threat to the normal operation of the power system and equipment. The microprocessors in electronic equipment, automatic control equipment and computers are usually more sensitive and have higher requirements for harmonic environments.

KLD-BMS series harmonic protector can absorb harmonic interferences of various frequencies and energies. Eliminating the occurrence of harmonics at the source can automatically eliminate the random high-order harmonics and high frequency noise, pulse spike, surge and other interferences to the power equipment. Harmonic protector can purify the power supply, protect the power equipment and power factor compensation equipment, prevent the false tripping of the protection device, so as to improve the operation efficiency and reliability of the equipment, reduce the cost of equipment maintenance and repair, and prolong the service life of the equipment.

EFFECTIVE PROTECTION AGAINST HIGH-FREQUENCY INTERFERENCE

  • Provide harmonic protection of various energies at frequencies of 1KHz-20MHz, eliminating high-order harmonics, high-frequency noise, pulse spikes, surges and other interferences.
  • Reduce the fault rate and misoperation of control equipment and other precise instruments to overcome the high-frequency interference caused by harmonic pollution.
  • Simple wiring, diverse installation positions, convenient commissioning, without routine maintenance.
High-frequency interference protection
Technical Parameters
Rated voltage110V~690V
Rated frequency50Hz/60Hz
Protection frequency1kHz~20MHz
Protection rangePulse withstand current≤16000A Single loop high-order harmonics(n≥20)Harmonic current≤40A
Response timeInstantaneous response time≤100us, full response time≤10ms
Instantaneous withstand voltagePulse withstand voltage2500V
Leakage current≤1.321mA
Power consumption<0.1W
Overload protectionSupported, with front circuit breaker
Protection degreeIIP40/P54 kit can be retrofitted
Installation methodGuide rail mounted
AltitudeConventional 2000 meters, higher altitude can be customized
Relative humidity≤95%RH(no condensing)
Storage temperature-50℃~+90℃
Temperature range-35℃~+80℃
Execution standardIEC61000-4-5, EC60939-1-2
GB14549-93 Quality of electric energy supply Harmonics in public supply network
GB12325-90 Quality of electric energy supply Admissible deviation of supply voltage
Technical Parameters
  • Rated voltage: 110V~690V

    Rated frequency: 50Hz/60Hz

    Protection frequency: 1kHz~20MHz

    Protection range: Pulse withstand current≤16000A Single loop high-order harmonics(n≥20)Harmonic current≤40A

    Response time: Instantaneous response time≤100us, full response time≤10ms

    Instantaneous withstand voltage: Pulse withstand voltage2500V

    Leakage current: ≤1.321mA

    Power consumption: <0.1W

    Overload protection: Supported, with front circuit breaker

    Protection degree: IIP40/P54 kit can be retrofitted

    Installation method: Guide rail mounted

    Altitude: Conventional 2000 meters, higher altitude can be customized

    Relative humidity: ≤95%RH(no condensing)

    Storage temperature: -50℃~+90℃

    Temperature range: -35℃~+80℃

    Execution standard: IEC61000-4-5, EC60939-1-2; GB14549-93 Quality of electric energy supply Harmonics in public supply network; GB12325-90 Quality of electric energy supply Admissible deviation of supply voltage

Selection Table

KLD-BMS Series

ModelVoltage(V)Installation methodProtection frequency
KLD-BMS99-3-400V400Guide rail mounted1kHz-20MHz
KLD-BMS100-3-400V400Guide rail mounted1kHz-20MHz
KLD-BMS300-3-400V400Guide rail mounted1kHz-20MHz
KLD-BMS500-3-400V400Guide rail mounted1kHz-20MHz
KLD-BMS1000-3-400V400Guide rail mounted1kHz-20MHz
KLD-BMS1000E-3-400V400Guide rail mounted1kHz-20MHz
Selection Table

KLD-BMS Series

  • Voltage(V):400

    Installation method:Guide rail mounted

    Protection frequency:1kHz-20MHz

  • Voltage(V):400

    Installation method:Guide rail mounted

    Protection frequency:1kHz-20MHz

  • Voltage(V):400

    Installation method:Guide rail mounted

    Protection frequency:1kHz-20MHz

  • Voltage(V):400

    Installation method:Guide rail mounted

    Protection frequency:1kHz-20MHz

  • Voltage(V):400

    Installation method:Guide rail mounted

    Protection frequency:1kHz-20MHz

  • Voltage(V):400

    Installation method:Guide rail mounted

    Protection frequency:1kHz-20MHz

Contact Us

Breaking barriers, innovating forward to achieve dual success at home and abroad, Dison Krod Group is honored as a National Green Factory and National SRUI "Little Giant" Enterprise..

Beijing Office: B31C, Universal Business Park, 10 Jiuxianqiao Road, Chaoyang District, Beijing City, China

Shanghai Office: Building 3, Convention & Exhibition Center of International Sourcing, No.235 Yunling East Road, Putuo District, Shanghai City, China

Hangzhou Office: Room 801, 8th Floor, Building 2, East Station Garden Business Center, No.768 Huanzhan East Road, Jianqiao Subdistrict, Shangcheng District, Hangzhou City, Zhejiang Province, China

Address

Kunshan Factory: No.666 Wengzi Road, Zhoushi Town, Kunshan City, Jiangsu Province, China

Hours

Monday-Friday: 9am to 6pm

Follow us

Send a message

Contact Form Demo