KLD-BMS2000 Series High Performance Harmonic Protector

Filtering harmonic frequency and energy, efficiently controlling harmonic interference, eliminating harmonics at the source.

PRODUCT OVERVIEW

Ideal power supply should be a sinusoidal waveform with a single constant frequency and specified amplitude. When a sinusoidal voltage is applied to a non-linear load, the current will be distorted into a non-sinusoidal waveform, which leads to a voltage drop in the grid impedance, making the voltage waveform turn to be non-sinusoidal as well. Applying Fourier series decomposition to non-sinusoidal waveforms, in which the component with the same frequency as the industrial frequency is called the fundamental wave, and the component with a frequency greater than the industrial frequency is called the harmonic wave.

KLD-BMS2000 series high-performance harmonic protector eliminates harmonics at the power side through digital logics and detects the current waveform generated by non-linear loads in the power grid in real time. It decomposes and reverses the harmonic wave, and then injects the reversed current into the power grid by triggering IGBT inverter to filter out the harmonics. It is mainly applied to the control of harmonics at the power side to protect the important power equipment of customers.

COMPREHENSIVE HARMONIC CONTROL CAPABILITY

KLD-BMS2000 series high-performance harmonic protector dynamically analyzes system harmonics in real time and filters them out to purify the system, and the response speed is very fast.

It automatically controls the harmonics according to the situation, and can filter out a wide range of harmonics, including 2nd to 71st harmonics. It can filter out the harmonics of phase A, B and C respectively, and the neutral line has the filtering capacity three times stronger than others, featuring comprehensive high-performance harmonic control.

Harmonic control capability

MODULAR DESIGN

KLD-BMS series high-performance harmonic protector adopts modular design with intelligent duct design, featuring lower loss and more convenient application.

It has complex model structure, wall-mounted and rack-mounted models are all designed in modules. Its compact space design and accurate capacity control can fully meet the needs of different customers, and applicable to a wide range of fields, making it very convenient in the transportation process, capacity increase and maintenance at the later stage. Also, the modular design is easier to be integrated into the power distribution cabinet.

Technical Parameters
System voltage110V~690V
Rated frequency50Hz/60Hz(±5%)
Filter range2nd-71st harmonics, the order and times of harmonics can be specified
Response timeTransient response time response time≤100ms, Full response time≤10ms
Filter effectUp to ≥97%
Communication protocolModbus protocol, RS485/232 module
Module designMultiple pcs in parallel
PF adjustmentAdjust PF from inductive 0.6 to capacitive 0.6
Switch frequency20kHz
Balance protectionProgrammable phase balance protection
Power consumption≤3% of its power consumption
Protection degreeIP21, high protection kit can be added
AltitudeConventional 2000 meters, higher altitude can be customized
Relative humidity≤95%RH(no condensing)
Temperature range-40℃~+65℃
Technical Parameters
  • System voltage: 110V~690V

    Rated frequency: 50Hz/60Hz(±5%)

    Filter range: 2nd-71st harmonics, the order and times of harmonics can be specified

    Response time: Transient response time response time≤100ms, Full response time≤10ms

    Filter effect: Up to ≥97%

    Communication protocol: Modbus protocol, RS485/232 module

    Module design: Multiple pcs in parallel

    PF adjustment: Adjust PF from inductive 0.6 to capacitive 0.6

    Switch frequency: 20kHz

    Balance protection: Programmable phase balance protection

    Power consumption: ≤3% of its power consumption

    Protection degree: IP21, high protection kit can be added

    Altitude: Conventional 2000 meters, higher altitude can be customized

    Relative humidity: ≤95%RH(no condensing)

    Temperature range: -40℃~+65℃

Selection Table

KLD-BMS2000 Series

ModelRated Compensation Current(A)Rated voltage(V)Installation methodCooling method
KLD-BMS2000-50A-400V50400Wall-mounted or rack-mountedForced air-cooling
KLD-BMS2000-100A-400V100400Wall-mounted or rack-mountedForced air-cooling
KLD-BMS2000-150A-400V150400Wall-mounted or rack-mountedForced air-cooling
KLD-BMS2000-200A-400V200400Wall-mounted or rack-mountedForced air-cooling
Selection Table

KLD-BMS2000 Series

  • Rated Compensation Current(A):50

    Rated voltage(V):400

    Installation method:Wall-mounted or rack-mounted

    Cooling method:Forced air-cooling

  • Rated Compensation Current(A):100

    Rated voltage(V):400

    Installation method:Wall-mounted or rack-mounted

    Cooling method:Forced air-cooling

  • Rated Compensation Current(A):150

    Rated voltage(V):400

    Installation method:Wall-mounted or rack-mounted

    Cooling method:Forced air-cooling

  • Rated Compensation Current(A):200

    Rated voltage(V):400

    Installation method:Wall-mounted or rack-mounted

    Cooling method:Forced air-cooling

Contact Us

Breaking barriers, innovating forward to achieve dual success at home and abroad, Dison Krod Group is honored as a National Green Factory and National SRUI "Little Giant" Enterprise..

Beijing Office: B31C, Universal Business Park, 10 Jiuxianqiao Road, Chaoyang District, Beijing City, China

Shanghai Office: Building 3, Convention & Exhibition Center of International Sourcing, No.235 Yunling East Road, Putuo District, Shanghai City, China

Hangzhou Office: Room 801, 8th Floor, Building 2, East Station Garden Business Center, No.768 Huanzhan East Road, Jianqiao Subdistrict, Shangcheng District, Hangzhou City, Zhejiang Province, China

Address

Kunshan Factory: No.666 Wengzi Road, Zhoushi Town, Kunshan City, Jiangsu Province, China

Hours

Monday-Friday: 9am to 6pm

Follow us

Send a message

Contact Form Demo